

- #ERROR OPENING PORT ERROR 57 LAN SPEED TEST SERIAL#
- #ERROR OPENING PORT ERROR 57 LAN SPEED TEST CODE#
- #ERROR OPENING PORT ERROR 57 LAN SPEED TEST PC#
- #ERROR OPENING PORT ERROR 57 LAN SPEED TEST OFFLINE#
These errors may occur on all screens if unsupported addresses are used by parts or functions that generate communication on all screens, for example, system data area, alarm, sampling, global D-script, global window, logic program.įollow the procedure below to check if any devices use unsupported addresses.įrom the GP-Pro EX menu, expand and select. The addresses of an unsupported connected device may be used by the parts on the screen or scripts. Is an error starting with RHAA036 to RHAA039 displayed?Įrrors starting with RHAA036 to RHAA039 are displayed when an address outside of the specified range is used. M.3.1 Checking the communication settings for the connected deviceĬheck the communication settings and IP address of the connected device by referring to the "GP-Pro EX Device/PLC Connection Manual" or the Device/PLC Connection Manual. To check the IP address specified for the connected device M.4.1 Assigning an IP address to the Display To check the IP address specified for the GP Check if the IP address of the connected device is set properly. (Example: ping 192.168.0.2)Ĭlick on the screen above to display the following dialog box. At the command prompt type "ping", space, and the IP address, then press the key.
#ERROR OPENING PORT ERROR 57 LAN SPEED TEST PC#
If the PC is located in a network, send the PING command to the GP and connected device and check whether they reply. Is an error starting with RHAA065 and RHAA066 displayed?Įrrors starting with RHAA065 and RHAA066 are displayed when there is a problem with the Ethernet communication. Check if the communication settings are valid by referring to the "GP-Pro EX Device/PLC Connection Manual".Ĭheck the communication settings of the connected device by referring to the "GP-Pro EX Device/PLC Connection Manual" or the Device/PLC Connection Manual.Ĭheck that the cable model and wiring are appropriate referring to the "GP-Pro EX Device/PLC Connection Manual".
#ERROR OPENING PORT ERROR 57 LAN SPEED TEST OFFLINE#
In the display unit's offline menu, from select.
#ERROR OPENING PORT ERROR 57 LAN SPEED TEST SERIAL#
When selecting in from the System Settings, and when the following screen is displayed, refer to the "GP-Pro EX Device/PLC Connection Manual", and verify whether the communication settings are properly set.įor example, when using Q/QnA serial communication series manufactured by Mitsubishi Electric CorporationĪlso check the communication settings in offline mode. Is an error starting with RHAA067 to RHAA070 displayed?Įrrors starting with RHAA067 to RHAA070 are displayed when there is a problem with RS-232C/422/485 communication. T.7.1 Settings common to all Display models *1 This chapter describes these errors only. Check the communication settings and cable connection. This is a typical error displayed when RS-232C/422/485 communication fails. Check the communication settings and IP address. This is a typical error displayed when Ethernet communication fails. For details, see the "GP-Pro EX Device/PLC Connection Manual". This error is caused by the connected device. This error is caused by the connected device.įor details, see the "GP-Pro EX Device/PLC Connection Manual".Īddress outside of the device range is used.Īn attempt was made to read data which is write-only.Īn attempt was made to write to data which is read-only. Check the port number and network environment. This error is displayed during Ethernet communication.


#ERROR OPENING PORT ERROR 57 LAN SPEED TEST CODE#
If communication fails on all screens, first check the error code displayed on the screen.Ĭheck if any noise is generated. T.4.1 Communication fails on all screens T.4.1 Communication fails on all screens
